Place of Origin: | China |
Hàng hiệu: | EuroKlimat |
Chứng nhận: | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Model Number: | EKDW-H |
Minimum Order Quantity: | 1 |
---|---|
Giá bán: | negotiable |
Packaging Details: | Plywood |
Delivery Time: | 15 working days after received your payment |
Payment Terms: | L/C, T/T |
Supply Ability: | 5,000pcs per month |
Product Name: | 30/50mm Insulation air flow air handling units | Installation: | Ceiling hang/floor installation |
---|---|---|---|
Cooling Capacity(kW): | 12-754 | Heating Capacity(kW): | 19-854 |
Air Flow(m3/h): | 2000-45000 | Aluminum Fins: | Shutter-type hyperbolic and hydrophilic fins |
Test Pressure (Mpa): | 3.3 | Coils rows: | 4/6 |
Làm nổi bật: | custom air handling units,chilled water air handling unit |
30/50mm PU Insulation double skin 2000 -45000 m3h air flow air handling units
EKDW series air handling units feature joggle structures and foamed polyurethane plates for effective heat preservation and service life enhancement. Units of this series have 40 models and 560 standard specifications available for your choice, and can be widely used in central air conditioning systems of hotels, shopping malls, hospitals, office buildings etc.
EKDW series units feature a high total external pressure, large cooling capacity, compact and simple structure and easy maintenance.
Easy maintenance:
the bearing of the fan motor needs no lubricant refill.
Low sound:
a quality fan motor with a low rev provides a large air flow with a low operation sound.
Clean and environment friendly:
A nylon filter with primary efficiency is installed at the air inlet. Customers can also choose to install a G3 plate or F7 bag filter and sterilization apparatus (aluminum screen filter, electric cleaner and photocatalyst are available).
A high-efficiency forward-pitched fan with multiple wings provides a large air flow and stable performance with a low operation sound. The bearing of the fan needs no lubricant refill, thus saving maintenance cost.
A 30/50mm-thickness strong cabinet wall made of foamed polyurethane ensures effective heat preservation and a long service life for the entire unit.
Mechanically expanded copper tubes with a thin wall and a new type of optimized wavy fins produced using leading-edge manufacturing facilities ensure optimal heat exchange efficiency and pave the way for a high EER. The coils feature multiple specifications and different types of loops to work in concert with various other sections.
Specifications
Model | EKDW 020H |
EKDW 030H |
EKDW 040H |
EKDW 050H |
EKDW 060H |
EKDW 070H |
EKDW 080H |
EKDW 090H |
EKDW 100H |
EKDW 120H |
EKDW 135H |
||
Nominal air flow (m3/h) | 2000 | 3000 | 4000 | 5000 | 6000 | 7000 | 8000 | 9000 | 10000 | 12000 | 13500 | ||
External residual pressure (Pa) | I | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | ~ | ~ | ~ | |
II | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | ||
III | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | ||
IV | ~ | ~ | ~ | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | ||
Nominal cooling capacity (kW) | 4 rows of coils (return air) | 12 | 17 | 24 | 31 | 38 | 44 | 51 | 56 | 63 | 74 | 81 | |
4 rows of coils (fresh air) | 29 | 42 | 57 | 69 | 83 | 94 | 113 | 127 | 142 | 169 | 175 | ||
6 rows of coils (return air) | 15 | 23 | 33 | 39 | 48 | 55 | 63 | 72 | 78 | 94 | 107 | ||
6 rows of coils (fresh air) | 35 | 53 | 69 | 88 | 105 | 122 | 137 | 155 | 173 | 208 | 237 | ||
Nominal heating capacity (kW) | 4 rows of coils (return air) | 19 | 30 | 41 | 50 | 61 | 71 | 83 | 93 | 103 | 122 | 140 | |
4 rows of coils (fresh air) | 33 | 49 | 66 | 82 | 99 | 115 | 133 | 148 | 161 | 197 | 220 | ||
6 rows of coils (return air) | 23 | 36 | 48 | 60 | 72 | 84 | 96 | 108 | 120 | 144 | 162 | ||
6 rows of coils (fresh air) | 38 | 57 | 77 | 95 | 114 | 132 | 150 | 169 | 188 | 224 | 255 | ||
Nominal cooling water flow (L/S) | 4 rows of coils (return air) | 0.57 | 0.81 | 1.14 | 1.48 | 1.81 | 2.10 | 2.43 | 2.67 | 3.00 | 3.52 | 3.86 | |
4 rows of coils (fresh air) | 1.38 | 2.00 | 2.71 | 3.29 | 3.95 | 4.48 | 5.38 | 6.05 | 6.76 | 8.05 | 8.33 | ||
6 rows of coils (return air) | 0.71 | 1.10 | 1.57 | 1.86 | 2.29 | 2.62 | 3.00 | 3.43 | 3.71 | 4.48 | 5.10 | ||
6 rows of coils (fresh air) | 1.67 | 2.52 | 3.29 | 4.19 | 5.00 | 5.81 | 6.52 | 7.38 | 8.24 | 9.90 | 11.29 | ||
Nominal heating water flow (L/S) | 4 rows of coils (return air) | 0.43 | 0.68 | 0.92 | 1.13 | 1.37 | 1.71 | 1.87 | 2.24 | 2.32 | 2.75 | 3.37 | |
4 rows of coils (fresh air) | 0.74 | 1.10 | 1.49 | 1.85 | 2.23 | 2.77 | 2.99 | 3.56 | 3.62 | 4.44 | 5.29 | ||
6 rows of coils (return air) | 0.52 | 0.81 | 1.08 | 1.35 | 1.62 | 2.02 | 2.16 | 2.60 | 2.70 | 3.24 | 3.90 | ||
6 rows of coils (fresh air) | 0.86 | 1.28 | 1.73 | 2.14 | 2.57 | 3.17 | 3.38 | 4.06 | 4.23 | 5.04 | 6.13 | ||
Coil | Type | Copper tube with a new type of wavy aluminum fins | |||||||||||
Piece/inch | 13 | ||||||||||||
Working pressure (MPa) | 1.6 | ||||||||||||
Size of inlet/outlet water pipe connector |
R1-1/2 | R1-1/2 | R1-1/2 | R1-1/2 | R1-1/2 | R2 | R2 | R2 | R2 | R2 | R2 | ||
Size of condensate water pipe connector |
R1-1/4 | ||||||||||||
Fan | Type/material | High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates | |||||||||||
Transmission | V-belt transmission | ||||||||||||
Fanning direction | Downward horizontal/top | ||||||||||||
Motor | Power supply | 380V/3~/50Hz | |||||||||||
Type | 3-phase asynchronous motor; insulation grade of F and protection grade of IP54 | ||||||||||||
Motor power (kW) |
I |
0.37 (0.37) |
0.55 (0.75) |
0.75 (0.75) |
0.75 (1.1) |
1.1 (1.1) |
1.1 (1.1) |
1.1 (1.5) |
1.5 (1.5) |
~ | ~ | ~ | |
II |
0.55 (0.55) |
0.75 (0.75) |
0.75 (1.1) |
1.1 (1.1) |
1.1 (1.5) |
1.1 (1.5) |
1.5 (1.5) |
1.5 (2.2) |
2.2 (2.2) |
3.0 (3.0) |
3.0 (3.0) |
||
III |
0.55 (0.75) |
0.75 (1.1) |
1.1 (1.1) |
1.1 (1.1) |
1.5 (1.5) |
1.5 (1.5) |
1.5 (2.2) |
2.2 (2.2) |
2.2 (2.2) |
3.0 (3.0) |
3.0 (4.0) |
||
IV | ~ | ~ | ~ |
1.1 (1.5) |
1.5 (2.2) |
1.5 (2.2) |
2.2 (2.2) |
2.2 (3.0) |
2.2 (3.0) |
3.0 (3.0) |
4.0 (4.0) |
||
Filter | Type | Thickness (mm) | |||||||||||
Thickness (mm) | 8/21 | ||||||||||||
Cabinet | Type | 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat preservation | |||||||||||
Unit Dimensions |
Length (mm) | 820 | 950 | 1010 | 1130 | 1260 | 1300 | 1500 | 1620 | 1650 | 1750 | 1940 | |
Width (mm) | 950 | 950 | 1050 | 1050 | 1050 | 1100 | 1100 | 1100 | 1050 | 1050 | 1050 | ||
Height (mm) | 630 | 650 | 755 | 755 | 805 | 830 | 830 | 830 | 890 | 950 | 950 | ||
Unit weight | 4 rows of coils (kg) | 127 | 141 | 169 | 184 | 209 | 233 | 266 | 283 | 348 | 367 | 393 | |
6 rows of coils (kg) | 131 | 147 | 176 | 192 | 219 | 245 | 280 | 298 | 366 | 388 | 416 |
Model | EKDW 150H |
EKDW 180H |
EKDW 200H |
EKDW 220H |
EKDW 250H |
EKDW 270H |
EKDW 300H |
EKDW 350H |
EKDW 400H |
EKDW 450H |
||
Nominal air flow (m3/h) | 15000 | 18000 | 20000 | 22000 | 25000 | 27000 | 30000 | 35000 | 40000 | 45000 | ||
External residual pressure (Pa) | I | ~ | ~ | ~ | ~ | ~ | ~ | 220 | 220 | 220 | 220 | |
II | 150 | 150 | 150 | 150 | 150 | 150 | 300 | 300 | 300 | 300 | ||
III | 220 | 220 | 220 | 220 | 220 | 220 | 400 | 400 | 400 | 400 | ||
IV | 300 | 300 | 300 | 300 | 300 | 300 | 500 | 500 | 500 | 500 | ||
V | ~ | ~ | ~ | ~ | ~ | ~ | ~ | 600 | 600 | 600 | ||
Nominal cooling capacity (kW) | 4 rows of coils (return air) | 97 | 114 | 123 | 134 | 155 | 165 | 191 | 220 | 256 | 286 | |
4 rows of coils (fresh air) | 211 | 248 | 270 | 290 | 337 | 361 | 418 | 481 | 558 | 620 | ||
6 rows of coils (return air) | 120 | 147 | 160 | 175 | 199 | 218 | 239 | 276 | 318 | 354 | ||
6 rows of coils (fresh air) | 268 | 321 | 347 | 375 | 434 | 459 | 526 | 596 | 686 | 754 | ||
Nominal heating capacity (kW) | 4 rows of coils (return air) | 153 | 186 | 202 | 225 | 253 | 277 | 310 | 358 | 408 | 460 | |
4 rows of coils (fresh air) | 246 | 296 | 326 | 355 | 406 | 439 | 502 | 574 | 656 | 730 | ||
6 rows of coils (return air) | 183 | 215 | 238 | 264 | 298 | 312 | 366 | 424 | 484 | 542 | ||
6 rows of coils (fresh air) | 287 | 338 | 375 | 412 | 469 | 507 | 574 | 666 | 766 | 854 | ||
Nominal cooling water flow (L/S) | 4 rows of coils (return air) | 4.62 | 5.43 | 5.86 | 6.38 | 7.38 | 7.86 | 9.10 | 10.48 | 12.19 | 13.62 | |
4 rows of coils (fresh air) | 10.05 | 11.81 | 12.86 | 13.81 | 16.05 | 17.19 | 19.90 | 22.90 | 26.57 | 29.52 | ||
6 rows of coils (return air) | 5.71 | 7.00 | 7.62 | 8.33 | 9.48 | 10.38 | 11.38 | 13.14 | 15.14 | 16.86 | ||
6 rows of coils (fresh air) | 12.76 | 15.29 | 16.52 | 17.86 | 20.67 | 21.86 | 25.05 | 28.38 | 32.67 | 35.90 | ||
Nominal heating water flow (L/S) | 4 rows of coils (return air) | 3.44 | 4.19 | 4.55 | 5.07 | 5.70 | 6.24 | 7.48 | 8.64 | 9.84 | 11.10 | |
4 rows of coils (fresh air) | 5.54 | 6.66 | 7.34 | 7.99 | 9.14 | 9.88 | 12.11 | 13.85 | 15.82 | 17.61 | ||
6 rows of coils (return air) | 4.12 | 4.84 | 5.36 | 5.94 | 6.71 | 7.02 | 8.83 | 10.23 | 11.68 | 13.07 | ||
6 rows of coils (fresh air) | 6.46 | 7.61 | 9.28 | 9.28 | 10.56 | 11.42 | 13.85 | 16.07 | 18.48 | 20.60 | ||
Coil | Type | Copper tube with a new type of wavy aluminum fins | ||||||||||
Piece/inch | 13 | |||||||||||
Working pressure (MPa) | 1.6 | |||||||||||
Size of inlet/outlet water pipe connector |
R2-1/2 | R2-1/2 | R2-1/2 | R3 | R3 | R3 | R3 | R3 | R3 | R3 | ||
Size of condensate water pipe connector |
R1-1/4 | |||||||||||
Fan | Type/material | High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates | ||||||||||
Transmission | V-belt transmission | |||||||||||
Fanning direction | Downward horizontal/top | |||||||||||
Motor | Power supply | 380V/3~/50Hz | ||||||||||
Type | 3-phase asynchronous motor; insulation grade of F and protection grade of IP54 | |||||||||||
Motor power (kW) |
I | ~ | ~ | ~ | ~ | ~ | ~ | 7.5(7.5) | 7.5(11) | 11(11) | 11(11) | |
II | 3.0(3.0) | 4.0(4.0) | 4.0(4.0) | 4.0(5.5) | 4.0(5.5) | 5.5(5.5) | 7.5(7.5) | 11(11) | 11(11) | 11(15) | ||
III | 3.0(4.0) | 4.0(4.0) | 4.0(5.5) | 5.5(5.5) | 5.5(5.5) | 5.5(7.5) | 11(11) | 11(11) | 15(15) | 15(15) | ||
IV | 4.0(4.0) | 4.0(5.5) | 5.5(5.5) | 5.5(7.5) | 5.5(7.5) | 7.5(7.5) | 11(11) | 11(15) | 15(15) | 15(15) | ||
V | ~ | ~ | ~ | ~ | ~ | ~ | ~ | 15(15) | 15(15) | 15(18.5) | ||
Filter | Type | Thickness (mm) | ||||||||||
Thickness (mm) | 8/21 | |||||||||||
Cabinet | Type | 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat preservation | ||||||||||
Unit Dimensions |
Length (mm) | 2010 | 2060 | 2250 | 2300 | 2470 | 2620 | 2770 | 2770 | 2930 | 2930 | |
Width (mm) | 1090 | 1090 | 1250 | 1250 | 1250 | 1250 | 1650 | 1650 | 1650 | 1810 | ||
Height (mm) | 1020 | 1140 | 1140 | 1200 | 1270 | 1270 | 1410 | 1570 | 1730 | 1890 | ||
Unit weight | 4 rows of coils (kg) | 447 | 477 | 565 | 589 | 703 | 722 | 972 | 1047 | 1196 | 1294 | |
6 rows of coils (kg) | 472 | 507 | 598 | 625 | 744 | 767 | 1025 | 1106 | 1266 | 1371 |
Note:
■ The above parameters are for standard units. However, EK can customize these parameters to meet special requirements from customers.
■ Working conditions for cooling under nominal return air flow: dry bulb 27°C, wet bulb 19.5°C; working conditions for cooling under nominal fresh air flow: dry bulb 34°C, wet bulb 28°C; water temperature under nominal cooling capacity: inlet water 7°C, outlet water 12°C.
■ Working conditions for heating under nominal return air flow: dry bulb 21°C; Working conditions for heating under nominal fresh air flow: dry bulb 0°C; water temperature under nominal heating capacity: inlet water 60°C, outlet water 50°C.
■ Weight listed in the above table are net weight of units. Operation weight may post an increase of 20%.
■ Parameters inside ( ) are the power of units with 6 rows of coils.
■ The coil loops for units with full return air ("R") and units with full fresh air ("F") may be different. Please specify the inlet air conditions while placing orders. EK can provide computer-aided model selection to meet special requirements. For detailed parameters, please refer to the model selection results.
1. All-round standard specifications for water flow, water pressure drop, etc
2. All-purpose secondary design software
3. Complete design flow for non-standard units to expand application scope
4. Wide access door makes maintenance work very convenient.
5. Optional accessories such as temperature/pressure drop alarms are available.
6. Both air inlet and outlet are equipped with a flange to facilitate air coil connection.
7. The unit can be mounted on the floor or hung from the ceiling.
Người liên hệ: Mr. LENG Zhengliang
Tel: +86 13828797702
Fax: 86-0769-83622528