Place of Origin: | China |
Hàng hiệu: | EuroKlimat |
Chứng nhận: | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Model Number: | EKDX |
Minimum Order Quantity: | 1 |
---|---|
Giá bán: | negotiable |
Packaging Details: | Plywood |
Delivery Time: | 15 working days after received your payment |
Payment Terms: | L/C, T/T |
Supply Ability: | 5,000pcs per month |
Product Name: | Air Handling Unit with condenser units | Installation: | Ceiling/floor installation |
---|---|---|---|
Cooling Capacity(kW): | 75-300 | Heating Capacity(kW): | 82.5-330 |
Air Flow(m3/h): | 30,000-60,000 | Aluminum Fins: | Shutter-type hyperbolic and hydrophilic fins |
Test Pressure (Mpa): | 3.3 | Coils rows: | 4/6 |
Làm nổi bật: | custom air handling units,hvac air handling unit |
Air flow 30,000-60,000 m3h direct expansion Air Handling Units with condenser unit
Features of EK clean-room air handling unit EK clean-room air handling unit is specifically designed for clean rooms. It provides a built-in cooling and heating source, integrates air handling and automatic control functions, and has the following features: low investment, simple system, efficient running, and easy installation and maintenance.
■ The unit has a simple design and easy control, and is suitable for independent use.
■ The indoor unit can be directly mounted to the ceiling or in an attached room, not requiring a special air-conditioner room.
■ No chilled or cooling water system is required. The control is simple. The project can be completed phase by phase at a low construction cost.
■ The maintenance is simple. Maintenance of a single unit requires only the space of the clean room.
■ The unit can run at temperature ranging from -10°C to 48°C.
Applicable to scenarios with constant-temperature constant-humidity control requirements
This unit is equipped with high-quality DDC controllers, basic direct-expansion coils, a primary-efficient filter (G4) and a medium-efficient filter (F8), pressure difference display control, non-step electric heating, a high-quality proportional electrode humidifier, and smart EK air-conditioner control solution, meeting requirements of a constant-temperature project for different granularity temperature and humidity control.
Specifications
Model | Indoor unit | EKDX300-75A/ EKDX300-75AR | EKDX300-150A/ EKDX300-150AR | EKDX400-200A/ EKDX400-200AR | EKDX500-250A/ EKDX500-250AR | EKDX600-300A/ EKDX600-300AR | |
Outd-oor unit | 2xEKAA150AB/ 2xEKAA150ARB |
4xEKAA150AB/ 4xEKAA150ARB |
8xEKAA100AB/ 8xEKAA100ARB |
8xEKAA125AB/ 8xEKAA125ARB |
8xEKAA150AB/ 8xEKAA150ARB |
||
Nominal cooling capacity (1) | kW | 75 | 150 | 200 | 250 | 300 | |
Nominal heating capacity (1) | kW | 82.5 | 165 | 220 | 275 | 330 | |
Nominal cooling capacity (2) | kW | 65 | 126 | 169 | 208 | 252 | |
Nominal heating capacity (2) | kW | 71.5 | 138 | 186 | 228 | 276 | |
Air flow | m3/h | 30000 | 30000 | 40000 | 50000 | 60000 | |
EKDM air handling unit model corresponding to the external height and width | EKDM1312H | EKDM1312H | EKDM1022H | EKDM1026H | EKDM1324H | ||
Refrigerant model | R22 | ||||||
Outer dimensions of indoor unit | Length | mm | As per the number of function sections | ||||
Height | mm | 2130 | 2130 | 1650 | 1650 | 2130 | |
Width | mm | 1970 | 1970 | 3620 | 4260 | 3940 | |
Outer dimensions of outdoor unit (W × D × H) |
mm |
2x1290x840 x1840 |
4x1290x840 x1840 |
8x990x840 x1840 |
8x990x840 x1840 |
8x1290x840 x1840 |
|
Compressor of outdoor unit | Model | Fully hermetic volute | |||||
Outdoor unit weight | kg | 2x285 / 2x300 | 4x285 / 4x300 | 8x265 / 8x280 | 8x270 / 8x285 | 8x285 / 8x300 | |
Power supply of outdoor unit | 380V/3N~/50HZ | ||||||
Cooling input power of outdoor unit | kW | 32.26 / 34.94 | 64.52 / 69.88 | 81.64 / 80.68 | 96.8 / 98.0 | 129.04 / 139.76 | |
Heating input power of outdoor unit | kW | -- / 29.4 | -- / 58.8 | -- / 81.2 | -- / 80 | -- / 117.6 | |
Connecting pipe specifications |
Liquid pipe |
φmm (in.) |
15.88(5/8) | 15.88(5/8) | 15.88(5/8) | 15.88(5/8) | 15.88(5/8) |
Gas pipe |
φmm (in.) |
34.9(1-3/8) | 34.9(1-3/8) | 28.6(1-1/8) | 28.6(1-1/8) | 34.9(1-3/8) | |
Connect mode | Soldering |
Note:
■ The nominal cooling capacity (1) is measured under the following conditions: The indoor dry/wet bulb reads 27/19 °C and the outdoor dry/ wet bulb reads 35/24 °C. The nominal heating capacity (1) is measured under the following conditions: The indoor dry bulb reads 20 °C and the outdoor dry/wet bulb reads 7/6 °C.
■ The nominal cooling capacity (2) is measured under the following conditions: The indoor dry/wet bulb reads 24/17 °C and the outdoor dry/wet bulb reads 35/24 °C. The nominal heating capacity (2) is measured under the following conditions: The indoor dry bulb reads 24 °C and the outdoor dry/wet bulb reads 7/6 °C.
■ The nominal cooling capacity does not consider heat losses of the fan motor of the indoor unit. The external static pressure can be customized, in which case the power of the air supply motor changes accordingly.
■ The specifications are subject to change due to product improvements without prior notice.
■ The fresh air flow of the unit cannot be larger than 20%.
Consolidated Structure
The unit features a compact structure, easy assembly, and solid seal. It adopts special seal glue handling, providing air leakage rate as low as 0.3%. The 30mm (standard)/50mm (optional) enhanced high-pressure non-fluorine polyurethane double-layer foamed panel delivers a solid insulation performance and high bearing capacity, meeting requirements of a purifying unit for high residual pressure.
High Efficient and Low Noise
The outdoor unit adopts brand-name fully hermetic volute compressors that deliver high efficiency, low noise, and strong resistance to hydraulic shock and run at temperature ranging from -10°C to 48°C, meeting cleaning requirements in various regions and scenarios.
The indoor unit adopts imported high-quality centrifugal fans with double air intakes (model selection of the fans has passed AMCA certification) or unhoused fans (optional), and is equipped with dedicated anti-vibration measures for quiet running.
Load Matching
The evaporation section of the indoor unit can be equipped with a bypass valve. The direct evaporation coil supports combination with multiple cooling capacity options according to different conditions for a wide range of fresh air/air return scenarios. The outdoor unit of a large-capacity cooling unit adopts modular design, allowing differential energy regulation during use, lowering the operating cost, and reducing shock on the grid at startup.
Sterilization
The indoor unit adopts a dry water drainage tray that has no residual condensed water and prevents bacteria. A stainless steel water tray is optional. In addition, a sterilization device such as efficient UV sterilization lamp and ozone generator can be configured as required to eliminate bacteria and effectively
suppress microbes in the system.
Saving Investment
The unit has a built-in cooling and heating source and does not require a chilled or cooling water system, greatly saving user investment, and making the unit structure simple and compact. No dedicated equipment room is required. The unit can run immediately after cabling and piping. The installation, use, and maintenance are easy.
Smart Control
The unit adopts integrated digital electromechanical design and is equipped with a smart controller, providing multiple control functions such as constant temperature, constant humidity, function setting, fault alarm, and remote monitoring to ensure safe and reliable unit running.
Prevention of Cold Bridge
The unit adopts inner skeleton design and high-strength foam seals and tight repair door structure, effectively preventing cold bridge between wall plates, between wall plate and inner skeleton,
or at the repair door. The panel of the unit is wrapped with solid insulating UPVC plastic at all sides, avoiding direct contact with thermal conductive parts, providing T1 class insulation performance, eliminating cold bridge, and preventing cooling loss.
High-Quality Filters
The unit adopts a high-quality multi-level (primary, medium, sub-high, and high efficiency) air filtering system. The filtering class meets the requirements of a special clean room, and can effectively suppress organic compounds on the filtering paper.
Purification Design
A special frame structure ensures smooth surface in the unit. The inner stainless steel surface and an efficient heat exchanger (optional) made of hydrophilic aluminum foil can effectively prevent dust accumulation and re-entrainment. The special design and materials can resist disinfectant and air erosion and are favorable for regular cleaning and sterilization.
Multi-System Design
The outdoor unit adopts modular design and starts level by level, efficiently reducing shock on the grid. Multiple levels of cooling are provided, allowing differential energy regulation under different load conditions and reducing the operating cost. The compressors wear in a balanced manner, prolonging the lifecycle.
Người liên hệ: Mr. LENG Zhengliang
Tel: +86 13828797702
Fax: 86-0769-83622528