Gửi tin nhắn
Nhà Sản phẩmCác đơn vị xử lý không khí

Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation

Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation

  • Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation
Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation
Thông tin chi tiết sản phẩm:
Place of Origin: China
Hàng hiệu: EuroKlimat
Chứng nhận: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKDM
Thanh toán:
Minimum Order Quantity: 1
Giá bán: negotiation
Packaging Details: Plywood
Delivery Time: 15 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 5,000pcs per month
Tiếp xúc
Chi tiết sản phẩm
Product Name: heating air handling units Installation: Ceiling/floor installation
Heating Capacity(kW): 7-1296 Air Flow(m3/h): 2,000-400,000
Aluminum Fins: Shutter-type hyperbolic and hydrophilic fins Test Pressure (Mpa): 3.3
Cooling Coils rows: 4/6 Heating coil rows: 1/2
Điểm nổi bật:

hvac air handling unit

,

chilled water air handling unit

 

 

Double skin 1/2 rows heating coil 7-1300kw  air handling units with 30/50 mm insulation

 

 

EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.

 

•   The surface  of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.


•    Internal panels are made of steel plates galvanized  with aluminum and zinc, with an assured  service life of more than 15 years. All panels  feature  end-to-end  joints and smooth surfaces, without any bur or corroded point.


•    The internal panels feature reinforced design, which is strong enough to support the largest  air handling unit.


•    The unit panel  has two thicknesses,  namely  30mm and 50mm.Inside  the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat- insulating material. The heat conductivity factor is less than 0.02W/m°C.


•    Each functional section of the unit is equipped  with a steel trough base, thus  ensuring  it is well supported,  easy to transport and assemble. The overall robustness of the unit meets the  standard of CEN2.

 

The unit features a special clamp structure, facilitating disassembly and maintenance as well as ensuring low air leakage. When the internal negative pressure is 1000Pa, the air leakage is below 1% (level B air leakage of European standard EN1886).

 

• The unit panels are coated with strong and heat-insulating UPVC plastics, thus avoiding direct contact between heat-conductive parts. With a heat-insulation grade of T1 (European standard), thermal bridge and cooling capacity loss are completely eliminated.

 

 

Specifciations 

 

 

Unit model EKDM Rated air flow m3/h 1 row 2 row
Return air conditions Fresh air conditions Return air conditions Fresh air conditions

Total cooling capa-

city kW

Water flow l/s

Water resis-

 

tance kPa

Pipe diam-

eter DN

Total cooling capa-city kW Water flow l/s

Water resis-

tance kPa

Pipe diam-

eter DN

Total cooling capa-

city kW

Water flow l/s

Water resis-

tance kPa

Pipe diam-

eter DN

Total cooling capa-

city kW

Water flow l/s

Water resis-

tance kPa

Pipe diam-

eter DN

306 2000 7 0.16 1 40 12 0.28 2 40 11 0.27 1 65 19 0.46 2 65
406 3000 10 0.23 1 40 17 0.41 3 40 16 0.4 1 65 29 0.7 2 65
407 4000 13 0.31 2 40 23 0.55 5 40 22 0.53 1 65 38 0.9 4 65
408 5000 16 0.40 3 40 28 0.68 8 40 27 0.67 2 65 47 1.17 6 65
508 6000 20 0.50 3 40 35 0.85 9 40 34 0.82 2 65 59 1.4 6 65
607 7000 22 0.55 3 40 39 0.95 8 40 37 0.9 2 65 65 1.6 6 65
608 8000 27 0.65 4 40 46 1.1 11 40 45 1.1 3 65 76 1.83 8 65
511 9000 32 0.80 9 40 54 1.3 23 40 53 1.3 7 65 90 2.2 18 65
610 10000 35 0.85 7 40 60 1.5 22 40 58 1.4 5 65 99 2.4 15 65
611 12000 41 1.00 11 40 70 1.7 29 40 69 1.67 8 65 116 2.8 21 65
712 15000 53 1.30 15 40 90 2.2 40 40 89 2.2 11 65 150 3.6 28 65
812 18000 63 1.50 16 40 107 2.6 46 40 105 2.5 12 65 178 4.3 33 65
813 20000 70 1.70 21 40 119 2.9 59 40 117 2.8 15 65 199 5 46 65
915 25000 92 2.20 22 50 154 3.7 59 50 153 3.7 17 50 256 6.2 43 80
1015 30000 108 2.60 24 40 172 4.22 15 40 180 4.4 18 65 300 7.4 48 65
1313 35000 122 3.00 20 40 206 5.1 55 40 204 5 15 65 344 8.4 39 65
1315 40000 142 3.40 27 40 228 5.6 19 40 238 5.8 21 65 402 10 59 65
1515 45000 164 4.00 30 40 260 6.2 20 40 272 6.6 22 65 456 11 59 65
1417 50000 180 4.40 43 40 288 7 28 40 302 7.4 32 65 484 12 20 65
1520 60000 212 5.20 11 40 360 8.8 32 40 352 8.8 9 65 596 14.8 24 65
1720 70000 244 6.00 9 40 416 10.2 24 50 408 10 7 50 688 16.8 17 80
1722 80000 276 6.80 12 40 472 11.6 32 50 468 11.6 9 50 784 19.2 23 80
1626 90000 292 7.20 3 50 504 12.4 8 50 532 13.2 14 50 888 21.2 33 80
1826 100000 324 7.84 3 50 568 14 9 50 592 14.4 14 50 1000 24.8 38 80
1852 200000 648 15.68 3 50 1136 28 9 50 1184 28.8 14 50 2000 49.6 38 80
3652 400000 1296 31.36 3 50 2272 56 9 50 2368 57.6 14 50 4000 99.2 38 80

 

Note:
■ Temperature of heated inlet water: 60°C; temperature drop 10°C.
■ Fresh air conditions for heating operation: inlet air temperature 0°C; return air temperature 21°C.
■ Coils are copper pipes with aluminum fins (12 fins/inch). EK can provide coils with 8~14 fins/inch.