Gửi tin nhắn
Nhà Sản phẩmCác đơn vị xử lý không khí

Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation

Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation

  • Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation
  • Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation
  • Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation
Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation
Thông tin chi tiết sản phẩm:
Place of Origin: China
Hàng hiệu: EuroKlimat
Chứng nhận: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKDW-V
Thanh toán:
Minimum Order Quantity: 1
Giá bán: negotiation
Packaging Details: Plywood
Delivery Time: 15 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 5,000pcs per month
Tiếp xúc
Chi tiết sản phẩm
Product Name: Vertical air handling units Installation: floor installation
Cooling Capacity(kW): 23-754 Heating Capacity(kW): 40-854
Air Flow(m3/h): 4000-45000 Aluminum Fins: Shutter-type hyperbolic and hydrophilic fins
Test Pressure (Mpa): 3.3 Coils rows: 4/6
Điểm nổi bật:

hvac air handling unit

,

chilled water air handling unit

EK keeps looking for valuable distributors and partners around international markets…

 

Vertical type cabinet F7 filter 4/6 rows coil air handling units with 30/50 mm PU insulation

 

EUROKLIMAT possesses the most advanced technologies and manufacturing facilities/processes in the air conditioning sector and has been forging ahead at the forefront of air conditioning products and technologies for more than 40 years by enterprising innovation.
 

Launched by EK to meet market demand, EKDW series air handling units feature joggle structures and foamed polyurethane plates for effective heat preservation and service life enhancement. Units of this series have 40 models and 560 standard specifications available for your choice, and can be widely used in central air conditioning systems of hotels, shopping malls, hospitals, office buildings etc.


Functional section

 

Mixing
Primary efficiency filter

Cooling coil

Heating coil

Wet film humidifier
Electric heater
Bag-type filter with medium efficiency

Fan 


Specifications

 

Model EKDW
040V
EKDW
050V
EKDW
060V
EKDW
070V
EKDW
080V
EKDW
090V
EKDW
100V
EKDW
120V
EKDW
135V
EKDW
150V
Nominal air flow (m3/h) 4000 5000 6000 7000 8000 9000 10000 12000 13500 15000
External residual pressure (Pa) I 80 80 80 80 80 80 80 ~ ~ ~
II 150 150 150 150 150 150 150 150 150 150
III 220 220 220 220 220 220 220 220 220 220
IV 300 300 300 300 300 300 300 300 300 300
Nominal cooling capacity (kW) 4 rows of coils (return air) 23 30 37 44 50 56.3 63 74 84 95
4 rows of coils (fresh air) 55 70 83 94 111 121 137 167 190 202
6 rows of coils (return air) 32 40 47 53 62 69 78 96 112 120
6 rows of coils (fresh air) 70 86 103 122 137 156 172 206 230 264
Nominal heating capacity (kW) 4 rows of coils (return air) 40 50 60 71 82 91 102 122 139 155
4 rows of coils (fresh air) 65 82 98 115 129 148 164 197 222 246
6 rows of coils (return air) 48 60 72 84 97 108 121 142 161 178
6 rows of coils (fresh air) 77 94 113 132 152 169 191 224 257 280
Nominal cooling water flow (L/S) 4 rows of coils (return air) 1.10 1.43 1.76 2.10 2.80 2.68 3.00 3.52 4.00 4.52
4 rows of coils (fresh air) 2.62 3.33 3.95 4.48 5.29 5.76 6.52 7.95 9.05 9.62
6 rows of coils (return air) 1.52 1.90 2.24 2.52 2.95 3.29 3.71 4.57 5.33 5.71
6 rows of coils (fresh air) 3.33 4.10 4.90 5.81 6.52 7.43 8.19 9.81 10.95 12.57
Nominal heating water flow (L/S) 4 rows of coils (return air) 0.96 1.21 1.45 1.71 1.98 2.19 2.46 2.94 3.34 3.74
4 rows of coils (fresh air) 1.57 1.98 2.36 2.77 3.11 3.56 3.96 4.75 5.34 5.93
6 rows of coils (return air) 1.16 1.45 1.74 2.02 2.34 2.60 2.92 3.43 3.87 4.29
6 rows of coils (fresh air) 1.86 2.27 2.73 3.17 3.67 4.06 4.61 5.40 6.18 6.75
Coil Type Copper tube with a new type of wavy aluminum fins
Piece/inch 13
Working pressure (MPa) 1.6
Size of inlet/outlet water
pipe connector
R 1-1/2 R 1-1/2 R 1-1/2 R 2 R 2 R 2 R 2 R 2 R 2 R 2-1/2
Size of condensate water
pipe connector
R1-1/4
Fan Type/material High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates
Transmission V-belt transmission
Fanning direction Top
Motor Power supply 380V/3~/50Hz
Type 3-phase asynchronous motor; insulation grade of F and protection grade of IP54
Motor power (kW) I

0.75

(0.75)

0.75

(1.1)

1.1

(1.1)

1.1

(1.1)

1.1

(1.5)

1.5

(1.5)

1.5

(2.2)

~ ~ ~
II

0.75

(1.1)

1.1

(1.1)

1.1

(1.5)

1.1

(1.5)

1.5

(1.5)

1.5

(2.2)

2.2

(2.2)

2.2

(2.2)

2.2

(3.0)

3.0

(3.0)

III

1.1

(1.1)

1.1

(1.1)

1.5

(1.5)

1.5

(1.5)

1.5

(2.2)

2.2

(2.2)

2.2

(2.2)

2.2

(3.0)

3.0

(3.0)

3.0

(4.0)

IV

1.1

(1.5)

1.1

(1.5)

1.5

(2.2)

1.5

(2.2)

2.2

(2.2)

2.2

(3.0)

2.2

(3.0)

3.0

(3.0)

3.0

(4.0)

4.0

(4.0)

Filter Type Thickness (mm)
Thickness (mm) 8/21
Cabinet Type 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat
preservation
Unit
Dimensions
Length (mm) 920 1030 1200 1230 1280 1290 1330 1440 1580 1870
Width (mm) 650 650 650 810 810 810 900 900 900 810
Height (mm) 1270 1335 1385 1490 1550 1610 1800 1860 1860 1680
Unit weight 4 rows of coils (kg) 172 203 236 274 306 323 386 423 435 482
6 rows of coils (kg) 179 211 246 286 321 339 404 444 458 507

 

 

Model EKDW
180V
EKDW
200V
EKDW
220V
EKDW
250V
EKDW
270V
EKDW
300V
EKDW
350V
EKDW
400V
EKDW
450V
Nominal air flow (m3/h) 18000 20000 22000 25000 27000 30000 35000 40000 45000
External residual pressure (Pa) I ~ ~ ~ ~ ~ 220 220 220 220
II 150 150 150 150 150 300 300 300 300
III 220 220 220 220 220 400 400 400 400
IV 300 300 300 300 300 500 500 500 500
V ~ ~ ~ ~ ~ ~ 600 600 600
Nominal cooling capacity (kW) 4 rows of coils (return air) 115 123 138 157 170 191 220 256 286
4 rows of coils (fresh air) 246 272 302 342 369 418 481 558 620
6 rows of coils (return air) 142 160 173 197 211 239 276 318 354
6 rows of coils (fresh air) 317 350 379 428 454 526 596 686 754
Nominal heating capacity (kW) 4 rows of coils (return air) 187 202 230 255 275 310 358 408 460
4 rows of coils (fresh air) 293 326 362 406 439 502 574 656 730
6 rows of coils (return air) 215 238 266 300 325 366 424 484 542
6 rows of coils (fresh air) 339 377 418 474 507 574 666 766 854
Nominal cooling water flow (L/S) 4 rows of coils (return air) 5.48 5.86 6.57 7.48 8.10 9.10 10.48 12.19 13.62
4 rows of coils (fresh air) 11.71 12.95 14.38 16.29 17.57 19.90 22.90 26.57 29.52
6 rows of coils (return air) 6.76 7.62 8.24 9.38 10.05 11.38 13.14 15.14 16.86
6 rows of coils (fresh air) 15.10 16.67 18.05 20.38 21.62 25.05 28.38 32.67 35.90
Nominal heating water flow (L/S) 4 rows of coils (return air) 4.51 4.87 5.55 6.15 6.63 7.48 8.64 9.84 11.10
4 rows of coils (fresh air) 7.07 7.86 8.73 9.79 10.59 12.11 13.85 15.82 17.61
6 rows of coils (return air) 5.19 5.74 6.42 7.24 7.84 8.83 10.23 11.68 13.07
6 rows of coils (fresh air) 8.18 9.09 10.08 11.43 12.23 13.85 16.07 18.48 20.60
Coil Type Copper tube with a new type of wavy aluminum fins
Piece/inch 13
Working pressure (MPa) 1.6
Size of inlet/outlet water
pipe connector
R 2-1/2 R 2-1/2 R 3 R 3 R3 R3 R3 R3 R3
Size of condensate water
pipe connector
R1-1/4
Fan Type/material High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates
Transmission V-belt transmission
Fanning direction Top
Motor Power supply 380V/3~/50Hz
Type 3-phase asynchronous motor; insulation grade of F and protection grade of IP54
Motor power (kW) I ~ ~ ~ ~ ~ 7.5(7.5) 7.5(11) 11(11) 11(11)
II 4.0(4.0) 4.0(4.0) 4.0(5.5) 4.0(5.5) 5.5(5.5) 7.5(7.5) 11(11) 11(11) 11(15)
III 4.0(4.0) 4.0(5.5) 5.5(5.5) 5.5(5.5) 5.5(7.5) 11(11) 11(11) 15(15) 15(15)
IV 4.0(5.5) 5.5(5.5) 5.5(7.5) 5.5(7.5) 7.5(7.5) 11(11) 11(15) 15(15) 15(15)
V ~ ~ ~ ~ ~ ~ 15(15) 15(15) 15(18.5)
Filter Type Thickness (mm)
Thickness (mm) 8/21
Cabinet Type 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure
for heat preservation
Unit
Dimensions
Length (mm) 2060 2250 2310 2480 2630 2770 2770 2930 3090
Width (mm) 810 900 900 900 900 1010 1010 1010 1170
Height (mm) 1740 1860 1920 1990 1990 2270 2590 2750 2810
Unit weight 4 rows of coils (kg) 537 649 674 779 807 968 1040 1196 1384
6 rows of coils (kg) 567 682 710 820 851 1021 1099 1267 1461

 

 

Note:
■ The above parameters are for standard units. However, EK can customize these parameters to meet special requirements from customers.
■ Working conditions for cooling under nominal return air flow: dry bulb 27°C, wet bulb 19.5°C; working conditions for cooling under nominal fresh air flow: dry bulb 34°C, wet bulb 28°C; water temperature under nominal cooling capacity: inlet water 7°C, outlet water 12°C.
■ Working conditions for heating under nominal return air flow: dry bulb 21°C; Working conditions for heating under nominal fresh air flow: dry bulb 0°C; water temperature under nominal heating capacity: inlet water 60°C, outlet water 50°C.
■ Weight listed in the above table are net weight of units. Operation weight may post an increase of 20%.
■ Parameters inside ( ) are the power of units with 6 rows of coils.
■ The coil loops for units with full return air ("R") and units with full fresh air ("F") may be different. Please specify the inlet air conditions while placing orders. EK can provide computer-aided model selection to
meet special requirements. For detailed

 

Aluminum Filter

■ Used to filter large particles, such as smog;
■ The aluminum frame helps to reduce maintenance cost;
■ The precision aluminum screen is easy to install and clean.

 

Electronic Purification Apparatus

 

■ A high-voltage static dedusting technology is applied to effectively filter all sorts of dust, bacteria,
virus and harmful gas;
■ Multi-layered filtering provides multi-layered protection;
■ A modular design can meet various air flow requirements.

 

Photocatalyst Ultraviolet Sterilamp

 

■ The sterilamp can effectively dampening the growth of bacteria and mildew and thereby
eliminating odor caused by such growth;
■ The photocatalyst itself is stable and unconsumed, and therefore can be effective for a long
time;
■ The sterilamp can effectively degrade contaminants such as formaldehyde, toluene and
ammonia into harmless and nontoxic materials, and does not cause secondary contamination.

 

Wet film humidifier
 

Tap water purified by the solenoid valve flows directly into the water distributor at the top of the
humidifier through water pipes and then flows down to wet the wet film under the pull of gravity.
Residual water collected by the water collector flows into the sewage through the drainpipe (water
will not be recycled). Hot air passing through the wet film is dampened and cooled (equal enthalpy
wetting). During this course, some water in the wet film is evaporated without consuming additional
energy. The work principle of wet film humidifier with direct water flow is shown in the figure on the
right side.

Chi tiết liên lạc
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Người liên hệ: Mr. LENG Zhengliang

Tel: +86 13828797702

Fax: 86-0769-83622528

Gửi yêu cầu thông tin của bạn trực tiếp cho chúng tôi (0 / 3000)

Sản phẩm khác